Work described
From the filingPower & Receptacles • Provide new and relocated 120V receptacles throughout renovated areas. • Install GFCI protection in kitchens, bathrooms, exterior, and other required locations. • Install AFCI protection on all required branch circuits. • Supply duplex, quad, split, USB, and special receptacles as per plans. Lighting & Controls • Install ceiling lights, recessed lighting, vanity lights, and other fixtures as shown. • Recessed light fixtures in insulated ceilings shall be IC-rated and airtight. • Provide switches, dimmers, and 3-way/4-way switching as required. • Coordinate with Owner on fixture selection; recessed housings included. • Lighting Package allowance for 64 recessed lights and 10 dimmers. • Final recessed lighting count to be confirmed prior to completion of rough-in. • Dimmer quantity to be finalized prior to trim-out/finish phase. Bathrooms & Ventilation • Provide power and switching for bathroom exhaust fan/light combinations. • Coordinate locations and CFM requirements with mechanical scope. Life Safety • Furnish and install hard-wired, interconnected smoke and CO detectors with battery backup per code and drawings. • Install heat detectors where indicated. Service Upgrade Allowance • New 200 Amp underground service with new 40/80 circuit 200 amp panel. • Upgrade to include complete new grounding system with 2 new ground rods, 2 new ground connections to water main and new ground bridge. • Install whole house surge protection by using a surge protection device at the panel as required by NEC. • Electrical Contractor to communicate with utility company and local town officials to complete installation on behalf of customer. • All work to be permitted by local town officials prior to the start of any work. • Excavation completed by others Conduit Allowance • Electrical contractor to provide 3 inch PVC conduit for power and 2 inch PVC conduit for data. Garage Addition • Provide and install complete electrical rough-in and trim-out for approximately 784 sq. ft. garage space, including routing and securing branch circuit wiring, installation of outlets and switches per code requirements, three (3) 20 amp dedicated circuits, lighting circuitry, panel tie-ins, and all necessary materials and labor to deliver a safe, functional, and code-compliant electrical system.
Browse
Permits in New London County, CTElectrical permitsInsulation permitsOpen bids in New London County
Other recent filings nearby
New London County, CT- Nov 2Roofing Permit - Quick Form
20 MAPLEWOOD CT, Norwich, CT 06360 · Norwich
- Nov 2Plumbing
102 HIGH MEADOW LN MYSTIC Groton CT 06355 · Groton
- Nov 2Plumbing
15 SPYGLASS CIR POQUONNOCK BRIDGE Groton CT 06340 · Groton
- Nov 2Electrical
8 INDIAN FIELD RD GROTON CT 06340 · Groton