Work described
From the filingResidential Service Equipment not exceeding a rating of 200 amps WITH AN INCREASE IN SERVICE SIZE FROM 100 AMP TO 200 AMP as per Residential Service Equipment EZ Standard Supply and install a new 200 AMP service including: A new 200 AMP service cable on the exterior sleeved in PVC conduit, if applicable, a new 200 AMP meter box, A new Eaton 200 AMP 40 circuit panel with main breaker, A new Eaton breaker properly sized for every existing circuit, supply and install an Eaton in panel surge protector, Ground the main electrical system, Build a backboard for the new equipment in the basement as necessary, label the panel, provide a permit and a third party inspection. Dining Room: Relocate existing outlet to lower standard height by either pulling wire down to new location or splicing at existing location and rewiring to new location. Kitchen Island: Provide GFCI protection to two island outlets by either existing GFCI outlets or a GFCI breaker in the main electrical panel. Pantry: Open up pantry outlet and properly ground as necessary if no rewiring is required. Fishing wires if necessary.: Please Note: Upgrading form existing 100 AMP service to 200 AMP service.