Work described
From the filingHardwiring a ChargePoint Home Flex EVSE inside the garage, set to 48-amps. Pulling #6 MC from the existing 200-amp panel to the Exterior wall of the home. Switching to 3/4-inch conduit and pulling #6 THHN/THWN-2 through the conduit. We will install a 60-amp breaker in the panel to protect the EVSE. This EVSE will also have load management to protect the EVSE from overloading the 200-amp service. The charger has built-in GFCI protection