Townline
Building permit · Hartford County, CT

Solar Panel - Roof mount

36 BANKS ROADSimsburySolarRoofing / siding / gutters

Work described

From the filing

Installing rooftop railed solar PV 10.66KW and 26 modules. Your application for a Building Permit has been reviewed for compliance with the 2022 State of Connecticut Building Code. The permit for the proposed work is approved. Please review our comments listed below. Conditions are subjected to field inspections. 1. NO STRUCTURAL UPGRADE IS REQUIRED- on the existing structure for installation of the array(s) as proposed, per provided engineer’s evaluation. 2. PV Array occupancy that is more than 33% of plan review total roof area, shall have a clear setback of not less than 36 inches on both sides of horizontals ridge. IRC R324.6.2 3. Roof access and pathways are to be provided per ’21 IRC section R324.6 of the ’22 CT State Building Code. 4. Provide Smoke and CO Detectors per IRC for alterations, repairs and additions. IRC R314.2.2, R315.2.2

Browse

Permits in Hartford County, CTSolar permitsRoofing / siding / gutters permitsOpen bids in Hartford County

Other recent filings nearby

Hartford County, CT
Solar Panel - Roof mount — 36 BANKS ROAD — Townline