Work described
From the filing****Dave IS ASSIGNED TO THIS**** COMMERCIAL WINTERBERRY GARDENS Rebuild the 50' x 50' section of the metal building that had the fire and was removed under a separate permit. The existing foundation and concrete slab are to be reused. The concrete piers will be modified to accommodate the new metal building structure. Build-out the interior of the 50'x50' section of new building with offices and toilet rooms. Includes a 50'x50' second floor with offices. Also, fit-out the adjacent existing shop bay (25'x50') into office area. The original foot print of the building will remain as is. The new 50'x50' section of the building will have a higher eave height of approx. 7.5' (existing building eave height is 16' and the new metal building eave height is 23.5') to accommodate the second floor and meet building code. Project will include plumbing, hvac and electrical work using existing utility services to the building. Engineered metal building drawings and engineered structural drawings for the pier modifications and framing are to follow. CO fee included