Permit

35 VINEYARD AVE GUILFORD Connecticut 06437

On HoldGuilford · HVAC / heating / cooling · filed Mar 24+4 more at this address

The generator will be connected to the 250 gal underground propane tank supply. New gas piping will be installed from the tank to the generator, sized per manufacturer requirements and fuel load calculations. All gas piping, shutoff valves, sediment trap, pressure testing, and connections will be installed in compliance with the International Fuel Gas Code (IFGC) and Liquified Petroleum Gas Code (NFPA58). Engineering Department Comments: Tank must be anchored to prevent from floating away (buoyancy). KIMBERLY NORMAN-ROSEDAM - CHIEF BUILDING OFFICIAL - PERMIT CONDITIONS: NFPA 58 APPENDIXES 1: LESS THAN 125 GALLONS – EXCHANGE TANK NON-FILLABLE MUST BE 5 FEET MIN, FILLABLE ON SITE MUST BE 10 FEET MIN AWAY FROM WINDOW A/C (SOURCE OF IGNITION) AND INTAKE TO DIRECT VENT APPLIANCE. SHALL COMPLY WITH 2021 IRC SECTION R322 FLOOD-RESISTANT CONSTRUCTION - MUST BE ANCHORED TO PREVENT FROM FLOATING AWAY (BUOYANCY) NOTES: 1. REGARDLESS OF ITS SIZE, ANY ASME TANK FILLED ON-SITE MUST BE LOCATED SO THAT THE FILLING CONNECTION AND FIXED LIQUID LEVEL GAUGE ARE AT LEAST 10 FEET FROM EXTERNAL SOURCE OF IGNITION (I.E. OPEN FLAME, WINDOW A/C, COMPRESSOR, ETC.), INTAKE TO DIRECT VENTED GAS APPLIANCE, OR INTAKE TO A MECHANICAL VENTILATION SYSTEM. 2. MAY BE REDUCED TO 10 FEET MINIMUM FOR A SINGLE CONTAINER OF 1200 GALLON WATER CAPACITY OR LESS IF IT IS LOCATED AT LEAST 25 FEET FROM ANY OTHER LP-GAS CONTAINER OF MORE THAN 125 GALLON WATER CAPACITY. 3. MINIMUM DISTANCES FROM UNDERGROUND CONTAINERS SHALL BE MEASURED FROM THE RELIEF VALVE AND FILLING OR LEVEL GAUGE VENT CONNECTION AT THE CONTAINER, EXCEPT THAT NO PART OF AN UNDERGROUND CONTAINER SHALL BE LESS THAN 10 FEET FROM A BUILDING OR LINE OF ADJOINING PROPERTY WHICH MAY BE BUILT UPON. 4. WHERE THE CONTAINER MAY BE SUBJECT TO ABRASIVE ACTION OR PHYSICAL DAMAGE DUE TO VEHICULAR TRAFFIC OR OTHER CAUSES IT MUST BE EITHER: A) PLACED NOT LESS THAN 2 FEET BELOW GRADE, OR B) OTHERWISE PROTECTED AGAINST SUCH PHYSICAL DAMAGE. SHALL COMPLY WITH TABLES 6.4.1.1 [SEPARATION DISTANCE BETWEEN CONTAINERS, BUILDING AND LINE OF ADJOINING PROPERTY] AND 6.4.4.3 [SEPARATION DISTANCE BETWEEN CONTAINERS PRESSURE RELIEF VALVE AND BUIILDING OPENINGS]

Valuation
Filed
Mar 24, 2026
Lot
1336

Locked on the free plan

Pro

Permit record

Permit no.
MECHRES--2603-000160
Municipality
Guilford
Block / lot
1336
Trade
HVAC / heating / cooling
Work type
Building - Mechanical LP Tank (Residential)

At this property

4 other permits
Same job
History