Permit

9 INWOOD DR GUILFORD CT 06437

IssuedGuilford · General contractor · filed Jul 23+2 more at this address

FINISHED BASEMENT WORK (WORK ALREADY DONE). FULL BATHROOM AND KITCHEN. NO BEDROOM. SUBS (ELECTRICAL AND PLUMBING) NOT INCLUDED IN VALUATION. KIMBERLY NORMAN-ROSEDAM - CHIEF BUILDING OFFICIAL - PERMIT CONDITIONS: SCOPE OF WORK - RESIDENTIAL ALTERATIONS (BASEMENT WITHOUT SLEEPING ROOM) WITH FULL BATHROOM AND KITCHEN. PERMIT CONDITIONS - WHERE APPLICABLE: 1. CONTINUOUS SANITARY FACILITIES TO BE MADE AVAILABLE TO PERSONS WHO WILL BE WORKING ON THE SITE OR BUILDING IN COMPLIANCE WITH 21-IRC SECTION 3305 AND 21-IPC SECTION 311 OF THE 22-CONNECTICUT STATE BUILDING CODE. SECTION R305 CEILING HEIGHT R305.1 Minimum height. Habitable space, hallways and portions of basements containing these spaces shall have a ceiling height of not less than 7 feet (2134 mm). Bathrooms, toilet rooms and laundry rooms shall have a ceiling height of not less than 6 feet 8 inches (2032 mm). R305.1.1 Basements. Portions of basements that do not contain habitable space or hallways shall have a ceiling height of not less than 6 feet 8 inches (2032 mm). Exception: At beams, girders, ducts or other obstructions, the ceiling height shall be not less than 6 feet 4 inches (1931 mm) from the finished floor. 1. NO SLEEPING AREA PERMITTED a. SLEEPING AREA IS CREATED MUST COMPLY WITH 2021 IRC AS AMENDED BY THE CONNECTICUT -2022 AMENDMENT TO THE STATE BUILDING CODE, SECTION R310.1 EMERGENCY ESCAPE AND RESCUE OPENINGS REQUIRED AND AMEND PERMIT HABITABLE SPACES LOCATED WITHIN BASEMENTS, AND HABITABLE SPACES WITHIN ATTICS, AND EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. OPENINGS SHALL COMPLY WITH SECTIONS R310.1.1 THRU R310.1.4 WITH MINIMUM NET CLEAR OPENING OF 5.7 SQFT, OPENING HEIGHT OF 24” CLEAR, OPENING WIDTH OF 20” CLEAR, MAX SILL HEIGHT OF 44” A.F.F. AND SHALL BE OPERATIONAL FROM INSIDE WITHOUT THE USE OF A KEY OR TOOL. REPLACEMENT WINDOWS ARE PERMITTED TO UTILIZE A REMOVABLE SASH TO ACHIEVE THE REQUIRED MINIMUM NET CLEAR OPENINGS. 2. COMPLY WITH 2021 IRC SECTION 303 - 303.4 AND 303.9 a. SUBMIT MANUFACTURER’S CUT SHEET OF PROPOSED HEATING UNIT AND LOAD CALCULATIONS FOR APPROVAL PRIOR TO ROUGH INSPECTIONS PERMITTEE AND PROPERTY OWNER ARE ADVISED THIS PERMIT IS ISSUED WITH THE FOLLOWING NOTIFICATIONS: 1) EFFECTIVE OCTOBER 1,2012 PUBLIC ACT 12·184 HAS BEEN ADOPTED WHENEVER ANY ALTERATION OR ADDITIONS TAKE PLACE IN A ONE- OR TWO-FAMILY DWELLING OCCUPIED DURING CONSTRUCTION THAT A BATTERY-OPERATED SMOKE ALARM AND A CO ALARM IF REQUIRED BE INSTALLED. PUBLIC ACT 12-184 CAN BE VIEWED @ HTTP://WWW.CGA.CT.GOV

Valuation
Filed
Jul 23, 2026
Lot
J0300010

Locked on the free plan

Pro

Permit record

Permit no.
BLDR--2607-000721
Municipality
Guilford
Block / lot
J0300010
Trade
General contractor
Work type
Building - Alteration, Interior Renovation, Remodel, or Repair (Residential)

At this property

2 other permits
Same job