6 STOCKADE ROAD

IssuedSimsbury · General contractor · filed Aug 5+6 more at this address

Daiken Ductless Split Heat Pump 48K BTU ODU unit with 5 heads. 18K btu wall mount living room, 9BTU wall mount upstairs, 9K btu wall mount master bedroom, 7ku wall mount small bedroom, 7K btu small bedroom Your application for a Building Permit has been reviewed for compliance with the 2022 State of Connecticut Building Code. The permit for the proposed work is approved. All work is subjected to field inspections. Comments below are to be reviewed and followed. 1. Indoor wall unit is required to have a water sensor on condensate pan. This can either be built in unit or a separate device. IRC M1411.3.1.1 2. Heating and cooling equipment and appliances are to be sized to meet supplied heat loss report. Along with follow ACCA Manual S or Manual J methodologies calculations. IRC M1401.3 3. Appliance installation is to follow all manufacturer’s instructions. IRC M1401.1 Revised plot plan needed 7/6