Remove existing shower & build new 4x5 shower with tiled floor, walls & ceiling SHOWER IS THE SAME SIZE Your application for a Building Permit has been reviewed for compliance with the 2022 State of Connecticut Building Code. The permit for the proposed work is approved. All work is subjected to field inspections. Comments below are to be reviewed and followed. 1.Provide Smoke and CO Detectors per IRC for alterations, repairs and additions. IRC R314.2.2, R315.2.2 2.Provide safety glazing as required per IRC. IRC R308.4.1 through R308.4.7 3.. When shower liners are water tight by materials from IRC P2709.2 and before tile is installed. A shower pan test will be required before membrane are concealed. This test is to follow all requirements of IRC P2503.6