Installation of 10.12kW DC code compliant roof-mounted solar array. Your application for a Building Permit has been reviewed for compliance with the 2022 State of Connecticut Building Code. The permit for the proposed work is approved. Please review our comments listed below. Conditions are subjected to field inspections. 1. NO STRUCTURAL UPGRADE IS REQUIRED- on the existing structure for installation of the array(s) as proposed, per provided engineer’s evaluation. 2. Roof access and pathways are to be provided per ’21 IRC section R324.6 of the ’22 CT State Building Code. 3. PV Array occupancy not more than 33% of plan view total roof area, shall have a clear setback of not less than 18 inches on both sides of horizontal ridge. IRC R324.6.2 4. Provide Smoke and CO Detectors per IRC for alterations, repairs and additions. IRC R314.2.2, R315.2.2
Locked on the free plan
ProPermit record
- Permit no.
- B-25-0966
- Municipality
- Simsbury
- Block / lot
- C17 604 005
- Trade
- Solar
- Work type
- Solar Panel - Roof mount
Property
Assessor record- Type
- Residential
- Built
- 1995
- Living area
- 3,641 sq ft
- Appraised
- $783,000
- Last sold
- $645,000 · Aug 2020