Permit

50 Morgan St

Permit IssuedNew Rochelle · General contractor · filed Aug 12

Upgrade existing electrical service to 200 amps for a single-family residence. Remove both meter bases and install one new 200-amp meter base and 200-amp service disconnect. Replace service riser with conduit, reconnect utility service, and upgrade grounding to current code. Replace existing panel with a new 200-amp panel, relocate the left panel to the former alarm box location, remove the alarm box and disconnect, relocate the Tesla circuit, convert the left panel to a 50-amp subpanel, and relabel all panels and circuits.

Valuation
$13.9K
Filed
Aug 12, 2026
Lot
2-546-0025

Locked on the free plan

Pro

Permit record

Permit no.
EP2026-0505
Municipality
New Rochelle
Block / lot
2-546-0025
Trade
General contractor
Work type
Electrical New / Increased Service

Property

Assessor record
Type
Single family
Built
1901
Living area
1,840 sq ft
Appraised
$386,010