36 MIANUS VIEW TERRACE
Provide necessary electrical work for necessary repairs and completion of electrical work for a final CO inspection; see attached list provided by electrical inspector for completing for final inspection and CO. Existing 400 amp. service. 2) all kitchen counter outlets, island outlets, dishwasher and outlets in basement cabinets need GFCI protection, 3) GFCI protection for washing machine outlet, 4) dryer outlet needs to be 4) wire type and plate 5) condensate pumps need outlets and wired 6) hallway outlets req'd in basement cabinets 7) closet rated fixtures required in all clothes closets 8) service GFCI outlets for all A/R Handlers 9) surge protection for service 10) clearances ifront of garage panel 9) 9 ground wire to water pipe wrong size, jumper water meter 10) gas pipe bonding incorrect on supply side, 11) inter system bonding block 12) all garage outlets and garage door opener outlets require GFCI protection 13) alarm outlet needs top outlet de-energized from yolk 14) quad outlet in basement utility room needs GFCI protection 16) FA letter 17) carbon monoxide/smoke detector required in hallway leading to garage dur to EV charger and heat detector in garage.